ELECTRO VOICE DX38 PDF

Dx38 can be used in networks of up to 31 controllers with a maximum networking distance of 1, meters. It has a mono sum of both input channels to maximize flexibility. Two configuration modes allow clearer handling for different qualified users. When you've added items to your cart you can go to the checkout page.

Author:Faukasa Maushicage
Country:Guatemala
Language:English (Spanish)
Genre:Literature
Published (Last):25 April 2011
Pages:343
PDF File Size:17.7 Mb
ePub File Size:3.27 Mb
ISBN:849-7-19026-928-8
Downloads:44643
Price:Free* [*Free Regsitration Required]
Uploader:Dousida



Quick Links. Download this manual See also: Service Manual. Table of Contents. Electrovoice compact precision cps: supplementary guide 2 pages. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with a damp cloth. Do not block any of the ventilation openings. Install in accordance with the manufactures instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.

The Dx 38 is an universal Digital Sound System Processor that provides 2 inputs and 4 outputs; plus internal summing of the inputs 1 and 2. Via matrix it is possible to assign the outputs to any input or to the sum of the inputs. The input signal can be amplified by up to 6 dB control set to its clockwise margin or attenuated by any degree. The Dx 38 is capable of handling mains voltages between 90 V AC to V AC, so that switching the mains on the appliance is not necessary.

Before switching on the power you have to connect the supplied European standard mains cord to the Dx 38 and your mains wall outlet. Upon initializing is complete, the last program that had been active before turning off the appliance is recalled.

For now, the display shows: Now, the Dx 38 is ready for operation. For a more detailed description of specific functions and parameters, please refer to the corresponding paragraph in the handbook. Here you can set the low-cut frequency for the selected channel.

Page Configurations Of The Dx 38 6. A configuration is a basic setting that includes the routing of inputs and outputs, the function of the outputs Sub, Lo, Mid, Hi, Fullrange , as well as the kind and amount of parameters. Page Program Selection 7. Altogether you have the possibility to choose from this selection of up to 80 different programs. Whenever the function block in the first line is selected, you are able to select another function block by using the rotary encoder Pressing one of the controls OUT 1 - 4 lets you directly select the function blocks of the corresponding output channel.

The program that was previously stored in this preset location is being erased! Please make sure, that the selected destination program number matches the number you want to save the program under.

Pressing any other key cancels the saving procedure. After saving is complete, the Store menu is automatically quitted and the display might look for instance like this: 7. Page Parameters 8. Additionally and to further improve operational comfort, corresponding parameters are linked. Page Parameter Link-Table 8. For instance, this allows to feed different PA-towers at open air concerts with delayed signals. The delay times are displayed in milliseconds and microseconds while the equivalent distances unit are displayed in feet, inches, meters or centimeters.

This guarantees the optimum frequency response that is matched to the connected loudspeaker components. Parameter Type Gain The setting is performed in steps with 1 dB-stepwidth. The Slope parameter describes the steepness or order of the filter for the low shelving or high shelving equalizers.

The parameters of the corresponding Lo-Pass should be set to the same values. The corresponding Hi-Pass filter should be set to the same cutoff frequency. Pol defines the polarity of the corresponding channel. They are used to compensate differences in loudspeaker dispersion plains that can be cabinet imminent or result from the positioning of individual loudspeaker cabinets or arrays.

The delay time or acoustical distance is displayed in milliseconds, microseconds, feet, inches, meters, or centimeters. Parameter Thrsh 0. The maximum level of the audio signal is limited to the set threshold value. The short attack times guarantee that even sudden peak levels are effectively attenuated. Volts: The threshold value is displayed in volts. RS IDs are set in the following menu. Page Midi The implementation chart is relevant for the software revision V1.

See also chapter 9. To reduce the risk of electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. If such malfunction occurs during the specified period, the product will be repaired or replaced at our option without charge. Print page 1 Print document 51 pages. Cancel Delete. Sign In OR. Don't have an account? Sign up! Restore password. Upload from disk. Upload from URL.

DVS 304 DVI PDF

Electro-Voice Dx38 Owner's Manual

.

LEXMARK INTERACT S605 PDF

Electro-Voice Dx38

.

CQM1-AD041 DATASHEET PDF

Electro-Voice DX38 Professional Digital Sound System Rack Mount Processor

.

Related Articles