AUTOCOLLIMATOR PDF

Encyclopedia … combined with a great Buyer's Guide! Note: this box searches only for keywords in the titles of encyclopedia articles. For full-text searches on the whole website, use our search page. Note: the article keyword search field and some other of the site's functionality would require Javascript, which however is turned off in your browser. Find more supplier details at the end of this encyclopedia article , or go to our.

Author:Moogusida Mooguzuru
Country:Mali
Language:English (Spanish)
Genre:Travel
Published (Last):5 January 2018
Pages:166
PDF File Size:5.59 Mb
ePub File Size:1.80 Mb
ISBN:675-5-61106-949-3
Downloads:9728
Price:Free* [*Free Regsitration Required]
Uploader:Gushicage



Choose products to compare anywhere you see 'Add to Compare' or 'Compare' options displayed. Optical Post Assemblies 0. Optical Pedestal Assemblies 1. Optical Post Assemblies 1. The controller is integrated in the body of the autocollimator making it ideal for systems integration or as a portable metrology tool.

Including the sensor noise, the sensitivity stays at 0. This feature is ideal for vibration measurements, structural drift, or even metrology applications like wobble measurements of bearings. This allows the user to manually and quickly setup the autocollimator. A calibration report is provided with each individual unit, certifying its performance.

If the unit is out of calibration, it can be returned to the factory for re-calibration. Once the GUI has been started, the layout is intuitive and straightforward. From the front panel, the user can access graphical displays of gathered data. This allows for easy setup, smaller footprint, lightweight design, and easy connections directly to the PC and power.

The dynamic acquisition mode allows collecting data continuously over a specified number of samples at a specific delay and the graphical display is updated on a real-time basis. When the acquisition is completed, data can be saved as a text file or an excel file.

Dynamic acquisition mode enables users to monitor a maximum angular deviation error in a setup over a specific time period. Other than angular measurements such as wobble, straightness and etc.

If users have an XPS series Universal controller or a third party data-logger ie. As data is constantly streamed through the analog output, the analog voltage gathered can be saved in the XPS controller. Industrial Motion. Custom Motion Solutions. Vacuum Compatible Motorized Positioners. Optical Posts 0. Lab Supplies. Custom Component Solutions. Diffraction Gratings. Fiber Optics. Optic Accessories.

Optic Sets. Custom Optics Solutions. Laser Diode Test Systems. Solar Cell Test Systems. Custom Vibration Isolation Solutions. Baratron Capacitance Manometers. Granville Phillips Vacuum Gauges. Mass Flow Controllers. Process Automation. Mass Spectrometers. MKS Instruments. Compare All. Products Features Accessories Resources. High sensitivity with angular measurements down to 0. Compatibility: All Metric Imperial. Autocollimator, Optical Head with Integrated Controller.

In Stock. Show All. Additional CAD file downloads are not available for this product. CAD File Downloads:. Additional drawings are not available for this product. Features Sensitive Angular Measurements. Fast Data Acquisition. Convenient Alignment Window. Certification and Quick Verification of Calibration.

Ideal Tool for Many Applications. The CONEX-LDS is ideal for: pitch and yaw measurements rotation stage accuracy measurements rotation axis orthogonality measurements surface flatness measurements settling time and stage damping analysis vibration analysis wobble control beam set-up and alignment machine alignments. Built-in Controller.

Sign In. Password Reset. Enter your email address below to reset your account password. Please Note: Your reset password applies to newport. Email Verification Required. Cart Merge. Check Order Status. Provide an order number and postal code to check the status of an order or download an invoice for an order that has shipped. Login to view your complete order history.

Sign In Required. To access this and other valuable technical resources, please sign in or register for a new online account.

Add to Cart. Shop at Newport. VAT ID has invalid format. It will not be saved with the order when submitted. Request Quote Continue Shopping. Cart Loading Quote Loading

KURZWEIL MICRO ENSEMBLEMANUAL PDF

Autocollimators

Choose products to compare anywhere you see 'Add to Compare' or 'Compare' options displayed. Optical Post Assemblies 0. Optical Pedestal Assemblies 1. Optical Post Assemblies 1. The controller is integrated in the body of the autocollimator making it ideal for systems integration or as a portable metrology tool.

GOGOL REVIZOR PDF

Autocollimator

Mehr erfahren. Video laden. YouTube immer entsperren. The TriAngle electronic autocollimators are non-contact optical test tools for the high-precision measurement of angular displacements of specular reflective surfaces and the accurate angular alignment of optical or mechanical parts. TriAngle autocollimators have a versatile modular design which allows them to be fitted with a wide selection of objective tubes, different sensors, reticles and light sources.

UPTON SINCLAIR LA JUNGLA PDF

CONEX-LDS Electronic Autocollimator

The Ultra Dual Axis Autocollimator gives high accuracy measurement of angle, straightness, flatness, squareness and parallelism. This digital autocollimator is controlled using a tablet PC with clear touch-screen software, using the latest CCD technology. Simple Set up This wide range Autocollimator comes with a laser sighting aid for simple setup. Combine this with the clear visual display on the autocollimators tablet PC and set up is easy even over long distances or with small reflectors.

CIRUGIA DE TORUS PALATINO PDF

Autocollimator is a versatile non-contact optical instrument for measurement of small angles or tilt movements with very high sensitivity. Holmarc manufactures precision visual autocollimators as well as electronics autocollimators as standard products and these instruments find multitude of applications in shop floor as well as metrology labs for precision measurements of straightness, parallelism, perpendicularity and flatness. Autocollimator projects the image of anilluminated reticle to the object under inspection and receive the reflected image from the object. In visual autocollimators this reflected image of reticle will focus at the position of fixed reference cross wire. Shift in reflected image compared to the fixed reference cross wire represents angle. A dual axis linear stage driven micrometers carry the fixed cross wire near the eyepiece of the instrument. Operator can determine shift and hence the angle by moving the fixed cross wire and aligning it with the reflected reticle image.

Related Articles